Showing results: 1 - 15 of 20 items found.
-
Langer EMV-Technik GmbH
The measurement coil is located vertically in the probe head. The near field probes are run with a positioning system (Langer Scanner).
-
Langer EMV-Technik GmbH
The measuring coil is horizontally located in the probe head. The near field micro probes are operated with a positioning system (Langer Scanner).
-
HD RANGER 3 -
PROMAX Electronica
The RANGER Neo 3 is a professional Field Strength Meter and Spectrum Analyzer that is part of a new breed of multifunction, TV, Satellite, CATV and WIFI analyzers.
-
MRC ltd.
This meter is used to indicate radiated electromagnetic fields. Wherever there is a voltageor a current, electric (E) and magnetic (H) fields arise.
-
WP400-3 -
Wavecontrol, S.L.
Wavecontrol presents a new and unique field probe for the measurement of electric and magnetic fields that integrates both E & H sensors within dimensions of only 3 cm². Which makes it unique is that Wavecontrol has managed to add an E field sensor in a basic structure of a classical 3 cm² field probe. It has been possible, therefore, to obtain a 3 cm² field probe without compromising the capability of assessing E and H fields of its 100 cm² big sister, the recognized and successful WP400.
-
TBPS01 -
TekBox Singapore Pte. Ltd.
The TBPS01 EMC near field probes H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation.
-
Ferrites India
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
1048 -
The Eastern Specialty Company
TESCO has recently updated the Field Bag. The newer Field Bag is slightly smaller than the previous version. The bag features a large main compartment with a removable divider, and two smaller side pockets. The Field Bag comes with a shoulder strap, for ease of mobility. The Field Bag measures 16″ x 8.75″ x 7.5″ (L x H x D).
-
Ferrites India
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
SF2 -
R&J Measurement
Electromagnet SF2 is a measuring circuits, which makes possible the generation of adequate values of static magnetic fields in air gap between the electromagnet poles, where the measured samples is placed. The range of magnetic field strength H amount from -1 650 to +1 650 [kA/m]
-
LS-ELF -
Lisun Electronics Inc.
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
HS6-DIFF-1000XMEG-W5 -
TEAM SOLUTIONS, INC.
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
sX series -
IT'IS Foundation
Exposure systems are equipment or systems designed for the assessment of, for example, health risk, efficacy of therapies or mechanisms associated with exposure to electromagnetic fields. The systems designed by the IT''IS Foundation are the sX series, where sX stands for "System for eXposure" with options for cells (c), vertebrates (v), and humans (h).
-
RF100 -
Laplace Instruments Ltd.
The RF100 probe set consists of a passive E field probe and H field probe, BNC adaptor and carry case. The output is via a BNC socket. These are general purpose probes which are ideal for use in conjunction with an EMC measuring system. They are sensitive to sources in close proximity, but are insensitive to background signals. This makes them ideal for the identification of emission frequencies in noisy environments... thus making measurements easier and quicker. The proximity requirement also enables sources to be located and the exit route identified.